Support

PSI-818 Series (800W-3000W) Pure Sine Wave High Frequency Inverter

PSI‑818 LCD Pure Sine Wave Automobile Inverter

PSI‑818 pure sine wave inverter converts 12VDC/24VDC battery power into stable AC power. Equipped with intuitive LCD display for real‑time monitoring of voltage, load rate and fault codes. It supports 50Hz/60Hz frequency and 220‑240V /110‑120V output adjustable on panel.

With low idle power loss and up to 90% conversion efficiency, this automobile inverter delivers clean sine‑wave power for household, camping and off‑grid loads. Multiple built‑in protections safeguard battery and devices against overload, over‑temperature and short‑circuit.

Share:
General Features
  • Colorful LCD display
  • AC output voltage 220-240V / 110-120V settable via LCD panel, 230 default
  • Output frequency 50Hz/60Hz settable via LCD panel, 50Hz default
  • Normal mode and Boost mode settabel via LCD panel, Boost mode default
  • Wired remote control with 6m cable
  • Additional output terminal (available for 1800W/2000W/2800W/3000W)
Technical Specifications
MODEL PSI-818-800W-12 PSI-818-1200W-12 PSI-818-1800W-12 PSI-818-2800W-12 PSI-818-1000W-24 PSI-818-1500W-24 PSI-818-2000W-24 PSI-818-3000W-24
Rated Power 800W 1200W 1800W 2800VA 1000VA 1500VA 2000VA 3000VA
Batery Voltage 12VDC 24VDC
DC INPUT
Battery Type Lead acid / LiFePO4
Input Voltage Range 9.5 – 15.5 VDC 19.0 – 31.0 VDC
Idle Current < 1A < 1.4A < 1.7A < 2.3A < 1A < 1.4A < 1.7A < 2.3 A
AC OUTPUT
Output Voltage 220V~ / 230V~, or 110V~ / 120V~
Output Frequency 50 Hz / 60 Hz
Output Waveform Pure sine wave
Efficiency Max 90%
DISPLAY
D Display Input voltage, output voltage, output frequency, battery capacity, load rate, error code
Setting Keys Output voltage, output frequency, output mode(boost mode or normal mode)
BATTERY PROTECITONS
Battery Reverse Connection 40A x 3 45A x 4 45A x 6 45A x 9 30A x 2 25A x 4 35A x 4 35A x 6
Battery Low Voltage Alarm When battery voltage <=10VDC, beeps slowly (once per 2 seconds).  Error code :06 When battery voltage <=20VDC, beeps slowly (once per 2 seconds).  Error code :06
Battery Low Voltage Alarm Recovery When battery voltage >= 11VDC When battery voltage >= 22VDC
Battery Low Voltage Cut & Shutdown When battery voltage <=9.5VDC, output cuts off, and buzzer beeps rapidly (once per second). Error code:01.  After 30s inverter shuts down automatically. When battery voltage <=19VDC, output cuts off, and buzzer beeps rapidly (once per second). Error code:01.  After 30s inverter shuts down automatically.
Battery Low Voltage Recovery When battery voltage >=12VDC When battery voltage >=24VDC
Battery High Voltage Cut & Shutdown When battery voltage >=15.5Vdc, output cuts off, and buzzer beeps rapidly (once per second).Error code:02. After 30s inverter shuts down automatically. When battery voltage >=31Vdc, output cuts off, and buzzer beeps rapidly (once per second), Error code:02. After v30s inverter shuts down automatically.
Battery High Voltage Recovery When battery voltage <=15VDC When battery voltage <=30VDC
OUTPUT PROTECTIONS
Overload Proteciton Boost mode: when load >=110%, inverter enters into boost mode, it will decreases the output voltage. With the increase of load, if the outpu voltage is less than 160V for 10s,  output cuts off, buzzer beeps rapidly (once per second). Error code: 05. After 30s inverter shuts down automatically.
Normal  mode: when load >=110%, inverter enters into boost mode, it will decreases the output voltage. With the increase of load, if the output voltage is less than 175V for 10s,  output cuts off, buzzer beeps rapidly (once per second). Error code: 05. After 30s inverter shuts down automatically.
Overload Recovery Removes unnecessary loads, manually restarts inverter( pressing ON/OFF button)
Short Circuit Protection Outputs cuts off, buzzer beeps rapidly (once per second). Error code:03.  After 30s inverter shuts down automatically.
Short Circuit Recovery Removes short circuit, manually restarts inverter( pressing ON/OFF button)
Over Temperature Alarm When temperature of key components over normal range, buzzer beeps rapidly (once per second). Error code: 07
Over Temperature Alarm Recovery When temperature of key components backs to normal range.
Over Temperature Protection Output cuts off, buzzer beeps slowly (once per 2 seconds). Error code: 04
Over Temperature Recovery Automatically restores output when temperature reaches to normal range
OTHERS
Output Sockets 1 x socket 1 x sockett + 1 x 3pin terminal 1 x socket 1 x sockett + 1 x 3pin terminal
Fan Smart cooling fan
USB Output 5VDC, 2.1A
Remote Control Wired remote control with 6m cable
OPERATING CONDITIONS
Storage Temperature -15°C ~ 40°C
Operating Temperature 0°C ~ 40°C
Operating Humidity 10%-90%, non-condensing
PACKING
Product Size (WxHxD mm)  280.4 x 159.6 x 88.8 310.4 x 159.6 x 88.8 375 x 195.5 x 99.3 432.5 x 195.5 x 99.3 280.4 x 159.6 x 88.8 310.4 x 159.6 x 88.8 375 x 195.5 x 99.3 432.5 x 195.5 x 99.3
Product Weight (kgs) 2.7 3.3 4.5 5.4 2.7 3.3 4.5 5.4
Inner Box Size (LxWxH mm) 332 x 205 x 142 365 x 205 x 142 423 x 250 x 173 480 x 250 x 173 332 x 205 x 142 365 x 205 x 142 423 x 250 x 173 480 x 250 x 173
Carton Size (LxWxH mm) 684 x 430 x 309 744 x 430 x 309 520 x 443 x 371 520 x 500 x 371 684 x 430 x 309 744 x 430 x 309 520 x 443 x 371 520 x 500 x 371
Qty / Carton (pcs) 8 4 8 4
Download